Envent Mobile Water Treatment Unit – VOC, pH and H2S Mobile Water Treatment Systems

Executive Summary

A remediation site had two multi-million-gallon runoff tanks filled with high-pH groundwater containing dissolved sulfur compounds. Draining required neutralization to pH 6–9 for discharge, but acid addition liberated massive H₂S (up to 60,000 ppm in headspace) and VOC vapors — creating both odor and safety risks.

Envent delivered a turnkey, dual-phase system in <72 hours**:

Result: Both tanks neutralized and emptied on schedule, zero odor complaints, zero H₂S exposure, full NPDES & RCRA compliance.

Project At A Glance

  • Location: U.S. Remediation Site
  • Challenge: Neutralize millions of gallons of high-pH water while controlling 60,000 ppm H₂S vapors
  • Solution: Acid injection + recirculating caustic scrubber + EMTOS thermal oxidizer
  • Outcome: Neutral pH achieved, zero emissions, tanks ready for reuse

The Challenge: High-pH Water + Massive H₂S Liberation Risk

  • Several million gallons of alkaline groundwater (pH >11)
  • Dissolved sulfur → 60,000 ppm H₂S released upon acidification
  • Must meet NPDES discharge limits (pH 6–9) and EPA RCRA air standards
  • Site surrounded by workers and nearby community — zero odor tolerance

Envent’s Turnkey Dual-Phase Treatment System

Phase Equipment & Envent Service Link Purpose
pH Neutralization Acid injection skid + recirculation loop + inline static mixer Fast, uniform pH reduction to 6–9
Primary H₂S Capture Recirculating Caustic Scrubber Neutralized up to 60,000 ppm H₂S
Final Destruction EMTOS Mobile Thermal Oxidizer >99.9% DRE of residual VOCs & H₂S
24/7 Monitoring pH, H₂S, LEL, flow Real-time data & auto-shutdowns

System ran continuously during recirculation and discharge with Envent operators on site.

Proven Results – Safe, Fast, Zero Emissions

Benefit Delivered Outcome
Neutralization Both tanks to pH 6–9 in days — ready for discharge
H₂S Control 60,000 ppm → 0 ppm at stack
Odor Elimination Zero complaints — even during peak off-gassing
Compliance 100% NPDES, RCRA, and local air permit compliant
Tank Availability Tanks emptied and returned to service on schedule

This remains one of the largest mobile pH-neutralization + H₂S vapor control projects ever executed.

Have high-pH water or H₂S risks blocking your tank or pond discharge? Get your Free NPDES-Compliant Treatment Plan & Quote today. Call Envent’s Water Team at 888-997-9465 or Request a Quote → — we make contaminated water discharge-ready, safely.